/**
 * jQuery Lightbox
 * Version 0.5 - 11/29/2007
 * @author Warren Krewenki
 *
 * This package is distributed under the BSD license.
 * For full license information, see LICENSE.TXT
 *
 * Based on Lightbox 2 by Lokesh Dhakar (http://www.huddletogether.com/projects/lightbox2/)
 * Originally written to make use of the Prototype framework, and Script.acalo.us, now altered to use jQuery.
 *
 *
 **/

(function($) {
	$.fn.lightbox = function(options) {
		// build main options
		var opts = $.extend({}, $.fn.lightbox.defaults, options);
        
		return $(this).live("click",function(){
			// initialize the lightbox
			initialize();
			start(this);
			return false;
		});
		
    /**
     * initalize()
     *
     * @return void
     * @author Warren Krewenki
     */
    function initialize() {
	    $('#overlay').remove();
	    $('#lightbox').remove();
	    opts.inprogress = false;
    
	    // if jsonData, build the imageArray from data provided in JSON format
      if (opts.jsonData && opts.jsonData.length > 0) {
	      var parser = opts.jsonDataParser ? opts.jsonDataParser : $.fn.lightbox.parseJsonData;                
	      opts.imageArray = [];
	      opts.imageArray = parser(opts.jsonData);
      }
    
	    var outerImage = '<div id="outerImageContainer"><div id="imageContainer"><iframe id="lightboxIframe" /><img id="lightboxImage"><div id="hoverNav"><a href="javascript://" title="' + opts.strings.prevLinkTitle + '" id="prevLink"></a><a href="javascript://" id="nextLink" title="' + opts.strings.nextLinkTitle + '"></a></div><div id="loading"><a href="javascript://" id="loadingLink"><img src="'+opts.fileLoadingImage+'"></a></div></div></div>';
	    var imageData = '<div id="imageDataContainer" class="clearfix"><div id="imageData"><div id="imageDetails"><span id="caption"></span><span id="numberDisplay"></span></div><div id="bottomNav">';

	    if (opts.displayHelp) {
		    imageData += '<span id="helpDisplay">' + opts.strings.help + '</span>';
			}

	    imageData += '<a href="javascript://" id="bottomNavClose" title="' + opts.strings.closeTitle + '"><img src="'+opts.fileBottomNavCloseImage+'"></a></div></div></div>';

	    var string;

	    if (opts.navbarOnTop) {
	      string = '<div id="overlay"></div><div id="lightbox">' + imageData + outerImage + '</div>';
	      $("body").append(string);
	      $("#imageDataContainer").addClass('ontop');
	    } else {
	      string = '<div id="overlay"></div><div id="lightbox">' + outerImage + imageData + '</div>';
	      $("body").append(string);
	    }

	    $("#overlay").click(function(){ end(); }).hide();
	    $("#lightbox").click(function(){ end();}).hide();
	    $("#loadingLink").click(function(){ end(); return false;});
	    $("#bottomNavClose").click(function(){ end(); return false; });
	    $('#outerImageContainer').width(opts.widthCurrent).height(opts.heightCurrent);
	    $('#imageDataContainer').width(opts.widthCurrent);

	    if (!opts.imageClickClose) {
	   		$("#lightboxImage").click(function(){ return false; });
	   		$("#hoverNav").click(function(){ return false; });
	    }
    };
	    
    function getPageSize() {
	    var jqueryPageSize = new Array($(document).width(),$(document).height(), $(window).width(), $(window).height());
	    return jqueryPageSize;
    };
	    
    function getPageScroll() {
	    var xScroll, yScroll;

	    if (self.pageYOffset) {
		    yScroll = self.pageYOffset;
		    xScroll = self.pageXOffset;
	    } else if (document.documentElement && document.documentElement.scrollTop){  // Explorer 6 Strict
		    yScroll = document.documentElement.scrollTop;
		    xScroll = document.documentElement.scrollLeft;
	    } else if (document.body) {// all other Explorers
		    yScroll = document.body.scrollTop;
		    xScroll = document.body.scrollLeft;
	    }

	    var arrayPageScroll = new Array(xScroll,yScroll);
	    return arrayPageScroll;
    };
	    
    function pause(ms) {
	    var date = new Date();
	    var curDate = null;
	    do{curDate = new Date();}
	    while(curDate - date < ms);
    };
	    
    function start(imageLink) {
	    $("select, embed, object").hide();
	    var arrayPageSize = getPageSize();
	    $("#overlay").hide().css({
				width: '100%', 
				height: arrayPageSize[1] + 'px', 
				opacity : opts.overlayOpacity
			}).fadeIn();
	    imageNum = 0;

	    // if data is not provided by jsonData parameter
      if (!opts.jsonData) {
      	opts.imageArray = [];
      	// if image is NOT part of a set..
      	if ((!imageLink.rel || (imageLink.rel == '')) && !opts.allSet) {
       		// add single image to Lightbox.imageArray
       		opts.imageArray.push(new Array(imageLink.href, opts.displayTitle ? imageLink.title : ''));
      	} else {
      		// if image is part of a set..
       		$("a").each(
						function() {
        			if(this.href && (this.rel == imageLink.rel)) {
	        			opts.imageArray.push(new Array(this.href, opts.displayTitle ? this.title : ''));
        			}
       			}
					);
      	}
	    }
	
	    if (opts.imageArray.length > 1) {
        for (i = 0; i < opts.imageArray.length; i++) {
		    	for (j = opts.imageArray.length - 1; j > i; j--) {
			    	if (opts.imageArray[i][0] == opts.imageArray[j][0]) {
				    	opts.imageArray.splice(j, 1);
			    	}
		    	}
	    	}
	
	    	while (opts.imageArray[imageNum][0] != imageLink.href) { 
					imageNum++;
				}
    	}

	    // calculate top and left offset for the lightbox
	    var arrayPageScroll = getPageScroll();
	    var lightboxTop = arrayPageScroll[1] + (arrayPageSize[3] / 10);
	    var lightboxLeft = arrayPageScroll[0];
	    $('#lightbox').css({top: lightboxTop+'px', left: lightboxLeft+'px'}).show();


	    if (!opts.slideNavBar) {
		    $('#imageData').hide();
			}

    	changeImage(imageNum);
   	};
	    
    function changeImage(imageNum) {
	    if (opts.inprogress == false) {
		    opts.inprogress = true;
		
				// update global var
		    opts.activeImage = imageNum;	

		    // hide elements during transition
		    $('#loading').show();
		    $('#lightboxImage').hide();
		    $('#hoverNav').hide();
		    $('#prevLink').hide();
		    $('#nextLink').hide();

				// delay preloading image until navbar will slide up
		    if (opts.slideNavBar) { 
			    $('#imageDataContainer').hide();
			    $('#imageData').hide();
			    doChangeImage();
		    } else {
		    	doChangeImage();
		    }
	    }
    };
	    
	  function doChangeImage() {
	    imgPreloader = new Image();

	    // once image is preloaded, resize image container
	    imgPreloader.onload = function() {
	      var newWidth = imgPreloader.width;
	      var newHeight = imgPreloader.height;

				if (opts.scaleImages) {
					newWidth = parseInt(opts.xScale * newWidth);
					newHeight = parseInt(opts.yScale * newHeight);
				}

		    if (opts.fitToScreen) {
          var arrayPageSize = getPageSize();
			    var ratio;
			    var initialPageWidth = arrayPageSize[2] - 2 * opts.borderSize;
			    var initialPageHeight = arrayPageSize[3] - 200;

					var dI = initialPageWidth/initialPageHeight;
					var dP = imgPreloader.width/imgPreloader.height;

					if ((imgPreloader.height > initialPageHeight) || (imgPreloader.width > initialPageWidth)) {
				    if (dI > dP) {
			        newWidth = parseInt((initialPageHeight/imgPreloader.height) * imgPreloader.width);
			        newHeight = initialPageHeight;
			    	} else {
		        	newHeight = parseInt((initialPageWidth/imgPreloader.width) * imgPreloader.height);
		        	newWidth = initialPageWidth;
			    	}
					}
	    	}

		    $('#lightboxImage').
					attr('src', opts.imageArray[opts.activeImage][0]).
					width(newWidth).
					height(newHeight);
		    resizeImageContainer(newWidth, newHeight);
	    };

		  imgPreloader.src = opts.imageArray[opts.activeImage][0];
		};
	    
   function end() {
	   disableKeyboardNav();
	   $('#lightbox').hide();
	   $('#overlay').fadeOut();
	   $('select, object, embed').show();
   };
	    
    function preloadNeighborImages() {
	    if (opts.loopImages && opts.imageArray.length > 1) {
	      preloadNextImage = new Image();
	      preloadNextImage.src = opts.imageArray[(opts.activeImage == (opts.imageArray.length - 1)) ? 0 : opts.activeImage + 1][0]
      
	      preloadPrevImage = new Image();
	      preloadPrevImage.src = opts.imageArray[(opts.activeImage == 0) ? (opts.imageArray.length - 1) : opts.activeImage - 1][0]
			} else {
				if ((opts.imageArray.length - 1) > opts.activeImage) {
					preloadNextImage = new Image();
					preloadNextImage.src = opts.imageArray[opts.activeImage + 1][0];
				}
				if (opts.activeImage > 0) {
					preloadPrevImage = new Image();
					preloadPrevImage.src = opts.imageArray[opts.activeImage - 1][0];
				}
			}
    };
	    
    function resizeImageContainer(imgWidth, imgHeight) {
			// get current width and height
			opts.widthCurrent = $("#outerImageContainer").outerWidth();
			opts.heightCurrent = $("#outerImageContainer").outerHeight();
   
			// get new width and height
			var widthNew = Math.max(350, imgWidth  + (opts.borderSize * 2));
			var heightNew = (imgHeight  + (opts.borderSize * 2));

			// calculate size difference between new and old image, and resize if necessary
			wDiff = opts.widthCurrent - widthNew;
			hDiff = opts.heightCurrent - heightNew;

			$('#imageDataContainer').animate({width: widthNew},opts.resizeSpeed,'linear');
 			$('#outerImageContainer').animate({width: widthNew},opts.resizeSpeed,'linear', function() {
				$('#outerImageContainer').animate({height: heightNew},opts.resizeSpeed,'linear', function() {
					showImage();
				});
			});

			// if new and old image are same size and no scaling transition is necessary,
			// do a quick pause to prevent image flicker.
			if((hDiff == 0) && (wDiff == 0)) {
				if (jQuery.browser.msie) { 
					pause(250); 
				} else { 
					pause(100);
				}
			}

			$('#prevLink').height(imgHeight);
			$('#nextLink').height(imgHeight);
    };
	    
    function showImage() {
	    $('#loading').hide();
	    $('#lightboxImage').fadeIn("fast");
	    updateDetails();
	    preloadNeighborImages();

	    opts.inprogress = false;
    };
	    
		function updateDetails() {
			$('#numberDisplay').html('');

			if (opts.imageArray[opts.activeImage][1]) {
				$('#caption').html(opts.imageArray[opts.activeImage][1]).show();
			}

			// if image is part of set display 'Image x of x'
			if (opts.imageArray.length > 1) {
				var nav_html;

				nav_html = opts.strings.image + (opts.activeImage + 1) + opts.strings.of + opts.imageArray.length;
				
				if (opts.displayDownloadLink) {
					nav_html += "<a href='" + opts.imageArray[opts.activeImage][0] + "'>" + opts.strings.download + "</a>";
				}				

				if (!opts.disableNavbarLinks) {
					// display previous / next text links
					if ((opts.activeImage) > 0 || opts.loopImages) {
						nav_html = '<a title="' + opts.strings.prevLinkTitle + '" href="#" id="prevLinkText">' + opts.strings.prevLinkText + "</a>" + nav_html;
					}

					if (((opts.activeImage + 1) < opts.imageArray.length) || opts.loopImages) {
						nav_html += '<a title="' + opts.strings.nextLinkTitle + '" href="#" id="nextLinkText">' + opts.strings.nextLinkText + "</a>";
					}
				}
				
				$('#numberDisplay').html(nav_html).show();
			}

			if (opts.slideNavBar) {
				$("#imageData").slideDown(opts.navBarSlideSpeed);
			} else {
				$("#imageData").show();
			}

			var arrayPageSize = getPageSize();
			$('#overlay').height(arrayPageSize[1]);
			updateNav();
		};
	    
    function updateNav() {
	    if (opts.imageArray.length > 1) {
		    $('#hoverNav').show();
                
				// if loopImages is true, always show next and prev image buttons 
				if(opts.loopImages) {
					$('#prevLink,#prevLinkText').show().click(function() {
						changeImage((opts.activeImage == 0) ? (opts.imageArray.length - 1) : opts.activeImage - 1); 
						return false;
					});

					$('#nextLink,#nextLinkText').show().click(function() {
						changeImage((opts.activeImage == (opts.imageArray.length - 1)) ? 0 : opts.activeImage + 1); 
						return false;
					});
		        
				} else {
					// if not first image in set, display prev image button
					if(opts.activeImage != 0) {
						$('#prevLink,#prevLinkText').show().click(function() {
							changeImage(opts.activeImage - 1); 
							return false;
						});
					}

					// if not last image in set, display next image button
					if(opts.activeImage != (opts.imageArray.length - 1)) {
						$('#nextLink,#nextLinkText').show().click(function() {
							changeImage(opts.activeImage +1); 
							return false;
						});
					}
				}
               
		    enableKeyboardNav();
	    }
    };
	    
		function keyboardAction(e) {
			var o = e.data.opts
			var keycode = e.keyCode;
			var escapeKey = 27;

			var key = String.fromCharCode(keycode).toLowerCase();

			// close lightbox
			if ((key == 'x') || (key == 'o') || (key == 'c') || (keycode == escapeKey)) { 
				end();
				
			// display previous image	
			} else if ((key == 'p') || (keycode == 37)) {  
				if(o.loopImages) {
					disableKeyboardNav();
					changeImage((o.activeImage == 0) ? (o.imageArray.length - 1) : o.activeImage - 1);
				} 
				else if (o.activeImage != 0) {
					disableKeyboardNav();
					changeImage(o.activeImage - 1);
				}
				
			// display next image
			} else if ((key == 'n') || (keycode == 39)) { 
				if (opts.loopImages) {
					disableKeyboardNav();
					changeImage((o.activeImage == (o.imageArray.length - 1)) ? 0 : o.activeImage + 1);
				}
				else if (o.activeImage != (o.imageArray.length - 1)) {
					disableKeyboardNav();
					changeImage(o.activeImage + 1);
				}
			}
		};
	    
		function enableKeyboardNav() {
			$(document).bind('keydown', {opts: opts}, keyboardAction);
		};

		function disableKeyboardNav() {
			$(document).unbind('keydown');
		};	    
	};
    
	$.fn.lightbox.parseJsonData = function(data) {
		var imageArray = [];

		$.each(data, function() {
			imageArray.push(new Array(this.url, this.title));
		});

		return imageArray;
	};

	$.fn.lightbox.defaults = {
		allSet: false,
		fileLoadingImage: '/images/loading.gif',
		fileBottomNavCloseImage: '/images/closelabel.gif',
		overlayOpacity: 0.8,
		borderSize: 10,
		imageArray: new Array,
		activeImage: null,
		inprogress: false,
		resizeSpeed: 350,
		widthCurrent: 250,
		heightCurrent: 250,
		scaleImages: false,
		xScale: 1,
		yScale: 1,
		displayTitle: true,
		navbarOnTop: false,
		displayDownloadLink: false,
		
		// slide nav bar up/down between image resizing transitions
		slideNavBar: false, 
		
		navBarSlideSpeed: 350,
		displayHelp: false,
		strings: {
			help: ' \u2190 / P - previous image\u00a0\u00a0\u00a0\u00a0\u2192 / N - next image\u00a0\u00a0\u00a0\u00a0ESC / X - close image gallery',
			prevLinkTitle: 'previous image',
			nextLinkTitle: 'next image',
			prevLinkText:  '&laquo; Previous',
			nextLinkText:  'Next &raquo;',
			closeTitle: 'close image gallery',
			image: 'Image ',
			of: ' of ',
			download: 'Download'
		},
		
		// resize images if they are bigger than window
		fitToScreen: false,		
		
    disableNavbarLinks: false,
    loopImages: false,
    imageClickClose: true,
    jsonData: null,
    jsonDataParser: null
	};	
})(jQuery);

